Product Detail
Product Tags
|
|
|
|
|
|
High integration design. Composeder by coolant cooling enclosure, cooling structure, connectors, fuse, 6.6kw on board charger, 2.0kw DC/DC converter. Implement the function of high voltage charging(240Vdc-450Vdc), low voltage charging(14V). dual PTC heating output terminal, one AC system output terminal, CAN communication, high voltage interlocking. Applicable to all kinds of passenger cars,logistics vehicles. 3 in 1 cooling chamber simplifies the whole design and increases the system reliability.
High voltage distribution
①AC input
|
|
②High voltage output |
③ Low voltage signal connector
|
④14V DC output |
OBC
AC Input
|
Other Features
|
Voltagesingle phase 90-264Vac(rated 220Vac)
|
EfficiencyEFF≥94%,Peak96%
|
Frequency50/60Hz±5%
|
Isolation2828VDC-Input to output≤10mA
|
Power factor>0.99@full load
|
2120VDC-Input to earth≤10mA
|
Harmonic current<5% @19.6A/336VDC@220VAC
|
2120VDC-Input to earth≤10mA
|
Input protectionsurge protection,AC over voltage protection,
|
MTBF≥300000H
|
Max input current≤32A
|
FunctionCC wake-up identifying function
|
Inrush currentLess than 110% of rated input current
|
CP detection function
|
DC Output
|
Real-time temperature monitor
|
Output voltage range240~450V adjustable
|
software sleep and wake-up
|
Max output power6.6KW
|
Communication mode CAN protocol
|
Max output current20A
|
heat-sink pad temperature range-20~55℃
|
Voltage regulation≤±0.5%
|
Cooling modeCoolant
|
Current regulation≤±1.5%
|
Protectionlevel IP67
|
Ripple≤±2%
|
Humidity5~95% no condensing
|
Voltage setting difference ≤±0.5%
|
|
Current setting difference ≤0.3A
|
|
Output protectionOver/under voltage protection
|
|
Over current protection
|
|
Short circuit protection
|
|
Over temperature protection
|
|
Power battery reverse connection protection
|
|
DCDC
DC INPUT
|
DC Output
|
Voltage200~450VDC
|
Rated output voltage14±0.2V
|
DC over voltage450VDC±10V
|
Output currentRated 0-143A Max 157A
|
DC under voltage190VDC±10V
|
Efficiency≥94.5%@143A、336VDC
|
Other Features
|
Rated output power2000W
|
Isolation3KVDC-Input to output
|
Output peak power2200W
|
3KVDC-Input to earth
|
Regulation accuracy≤±1%
|
Communication mode CANprotocol
|
Overshoot of output voltage ≤±5%
|
Operating temp-40℃~70℃(70℃~85℃linearly derating)
|
Ripple≤300mV@336VDC
|
Humidity5~95%temp 40°C no condensation
|
Output protectionShort circuit protection
|
|
Output over voltage protection
|
|
Output current limited protection
|
|
Over temperatue protection
|
|
Part No. |
Description |
PCS/CTN |
G.W.(KG) |
CMB(m3) |
OrderQty. |
Time |